Upravit stránku

Save on heating materials and get a hot steam generator. If you heat your brewer with steam, a hot steam generator is an ideal economic solution for you.

  • A.V. 50

    Steam production

    50 kg/h

    Output

    34,7 kW/h

    Working pressure

    5 bar

    Gas consumption

    3.5 m³/h

    ELHO consumption

    3 kg/h

    LPG consumption

    2.5 kg/h

    LPG consumption

    1.1 m³/h

    Power consumption

    0,75 KVA

    Steam output

    ½"

    Flue pipe throat

    140 mm

    Flue gas overpressure

    0.5 Mbar

    Weight

    250 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1 130 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V.100

    Steam production

    100 kg/h

    Output

    67,7 kW/h

    Working pressure

    5 bar

    Gas consumption

    7 m³/h

    ELHO consumption

    6 kg/h

    LPG consumption

    5 kg/h

    LPG consumption

    2.2 m³/h

    Power consumption

    0.75 KVA

    Steam output

    ½"

    Flue pipe throat

    140 mm

    Flue gas overpressure

    1.2 Mbar

    Weight

    260 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1 130 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V.120

    Steam production

    120 kg/h

    Output

    90 kW/h

    Working pressure

    5 bar

    Gas consumption

    9 m³/h

    ELHO consumption

    7.8 kg/h

    LPG consumption

    6.5 kg/h

    LPG consumption

    2.8 m³/h

    Power consumption

    0.75 KVA

    Steam output

    ½"

    Flue pipe throat

    140 mm

    Flue gas overpressure

    1.8 Mbar

    Weight

    310 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1130 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 150

    Steam production

    150 kg/h

    Output

    112.7 kW/h

    Working pressure

    5 bar

    Gas consumption

    11.5 m³/h

    ELHO consumption

    9.7 kg/h

    LPG consumption

    8 kg/h

    LPG consumption

    3.6 m³/h

    Power consumption

    0.75 KVA

    Steam output

    3/4"

    Flue pipe throat

    180 mm

    Flue gas overpressure

    2.5 Mbar

    Weight

    340 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1400 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 200

    Steam production

    200 kg/h

    Output

    151 kW/h

    Working pressure

    5 bar

    Gas consumption

    15 m³/h

    ELHO consumption

    13 kg/h

    LPG consumption

    10.8 kg/h

    LPG consumption

    4.8 m³/h

    Power consumption

    0.75 KVA

    Steam output

    3/4"

    Flue pipe throat

    180 mm

    Flue gas overpressure

    2.8 Mbar

    Weight

    370 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1400 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 220

    Steam production

    220 kg/h

    Output

    166 kW/h

    Working pressure

    5 bar

    Gas consumption

    15 m³/h

    ELHO consumption

    14.3 kg/h

    LPG consumption

    11.9 kg/h

    LPG consumption

    5.3 m³/h

    Power consumption

    0.75 KVA

    Steam output

    3/4"

    Flue pipe throat

    180 mm

    Flue gas overpressure

    3 Mbar

    Weight

    400 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1400 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 250

    Steam production

    250 kg/h

    Output

    189 kW/h

    Working pressure

    5 bar

    Gas consumption

    19 m³/h

    ELHO consumption

    16.2 kg/h

    LPG consumption

    13.5 kg/h

    LPG consumption

    6 m³/h

    Power consumption

    1.5 KVA

    Steam output

    1"

    Flue pipe throat

    200 mm

    Flue gas overpressure

    3.5 mbar

    Weight

    430 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1670 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 300

    Steam production

    300 kg/h

    Output

    227 kW/h

    Working pressure

    5 bar

    Gas consumption

    23 m³/h

    ELHO consumption

    19.2 kg/h

    LPG consumption

    16.2 kg/h

    LPG consumption

    7.2 m³/h

    Power consumption

    1.5 KVA

    Steam output

    1"

    Flue pipe throat

    200 mm

    Flue gas overpressure

    4 Mbar

    Weight

    460 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1670 mm

    Width mm

    1200 mm

    Depth

    700 mm

  • A.V. 350

    Steam production

    350 kg/h

    Output

    264 kW/h

    Working pressure

    5 bar

    Gas consumption

    27 m³/h

    ELHO consumption

    22.7 kg/h

    LPG consumption

    18.9 kg/h

    LPG consumption

    8.4 m³/h

    Power consumption

    1.5 KVA

    Steam output

    1"

    Flue pipe throat

    200 mm

    Flue gas overpressure

    5 Mbar

    Weight

    490 kg

    Length of burner nozzles

    200/250

    Height without the burner

    1670 mm

    Width mm

    1200 mm

    Depth

     

Write for a free offer

  • Fields marked with an asterisk (*) are required.
Nahoru